Friday, 12 February 2016
Digiprog 3 Odometer Programmer error solution
Solution: This one is the normal prompt. Click the √, and input password 1, then go on to use it as before.
More information:http://www.obdexpress.co.uk/wholesale/main-unit-digiprog3-iii-digiprog-3-odometer-programmer.html
Thursday, 21 January 2016
2016 VBOX-VOLVO XC90 Diagnostic Tool Scanner for Volvo
Language: English
Software system support: Window XP/7/8/10
Update: Free ( If add additional special function on this device, update may charges)
How to use VBOX-VOLVO XC90 Diagnostic Tool
1. Connect to hardware, insert the box into OBD interface, connect the box with internet reticle and computer reticle interface, red light sparkling. You can find the OBD interface on the left side down of the seat.
Hardware lights instruction
LED status Status instruction
Red light sparkling hardware working ok
Green light sparkling data communication status
2. UDVOLVO is a free install application, decompression zip package to local computer folder, run the application…/Volvo/ASAMMCD3/UDVolvo.exe press enter after you find your vehicle IP.
3. Press“Vehicle identification number, read ECU information, read fault number
4. Double press “current fault code number”, enter single ECU
Press“current fault code number or history fault code number”, press the right button on mouse go check for detail information.
5. Check the detail information.
6. Check the fault code number detail information.
7. Check ECU detail information.
8. Enter ECU read fault code number history fault code number, clean up code number, read vehicle identification number and ECU detail information, press current “current fault code number and history fault code number” to clean up the fault code numbers.
http://www.foxwelltool.com
Sunday, 10 January 2016
VAS 5054A ODIS over VAS-PC V19
1) Need (or no) to install VAS UDS additional exe files ?
Answer : (For VAS-PC v19 and WinXP)
For old Adapter = VID_077E&PID_0220 = Not Need
Device Name = Softing Vehicle Interface \ VAS5054
DRV = C:/SIDIS/home/DBaseSys2/Driver/EDIC/win2000 (Default VAS-PC v19)
For new adapter ( v2.05 ) = VID_0403&PID_6001 = Need !!!
Device Name = VAS5054 BUS
DRV = REQUIRED = VAS5054A UDS Redist Drivers Package
After Install Drv Path = C:\Program Files\VCI\USB
2) Default D-PDU API = v1.10 (for Vas-Pc v19.01.01) ...
Need (or no) update it to v1.23 ?
Answer : (may be for ODIS only ...)
Good China adapter must work to API 1.35
Bad China adapter don't work after API 1.20 ... 1.23
Version reduced if the adapter can not communicate with the car ...
For change path = may be here ? : pdu_api_root.xml
3) Will both of these programs work on the same PC ?
Answer : Yes, if the condition is fulfilled ...
3a = Adapter VAS5054 have the same setting in both soft's
3b = ImporterID , DealerID have the same setting in both soft's
3c = If VAS-PC v19.01.01 = It should be no problem ...
3d = If VAS-PC NOT v19.01.01 = Install VAS-PC, ODIS, Re-Install VAS-PC (or recovery)
4) What should I do before starting the installation ?
Answer : for ODIS ; nothing special ... Clean new OS Win7 ...
Install Java j2sdk-1_4_2_15 or j2re-1_4_2_15 (reccomended by VAG)
Edit License (to match to PC)
Tuesday, 5 January 2016
Ford VCM error: cable between ids and vcm not detected (SOLVED)
have change the IP address to 172.16.0.1 in Control panel/network. Everyone make this mistake. Ford VCM works on LAN.The small black box in the middle of the cable is USB to LAN convertor.You will see in the network adapters that there is Realtek 8185 (or someone other network adapter i forget the name) change the automatic IP to static IP with 172.16.0.1
And beware Ford VCM can work only on main USB on your Laptop.Try to attach the VCM on every USB and you will see that IP address is change all time. only on one USB, VCM can work.
BEST-quality Ford VCM II clone with wireless card, to better diagnose, do programming, and avoid less troubles:
http://www.obdexpress.co.uk/wholesale/best-ford-vcm-ii-diagnostic-tool-wifi-wireless-version.html
Friday, 1 January 2016
New arrival European software for XPROG 5.55 ATMEGA64 Repair Chip
ATMEGA64 Repair Chip update XPROG-M ECU Programmer from V5.0/V5.3/V5.45/V5.50 to V5.55 Full Authorization (Including CAS4) with stable European software is available at obd2express.co.uk
New features of the XPROG 5.55 ATMEGA64 Repair Chip
1. European solution on XPROG-M software, tested for all versions, very reliable.
2. Supports any XPROG-M Version update, all can be updated to latest V5.55
3. Supports ALL authorizations (including CAS4).
How to use the xprog update chip:
First, Our update chip and software suitable for any version XPROG-M Hardware. Our package only include update chip and software, not include XPROG-M hardware.
Second, we ship the update chip and software from European directly by post service.
Third, after you receive the update chip, solder new Atmega64 MCU to your xprog. Overwrite all files and folders from Xprog_Preinstalled,to your native Xprog install. Usualy C:\Program Files\ELDB\Xprogor C:\Program Files(X86)\ELDB\Xprog.
You can now start and Run Xprog. If you want to use this version on brand new PC, please install Xprog 5.0 and Adobe acrobat reader prior to files copy.
XPROG-M V5.55 Software Display:
Wednesday, 30 December 2015
VVDI MB Tool 2.0.4 Add Mercedes BGA Key Step by Step
OBD2EXPRESS technicians has successfully added BGA keys of Benz W166, 197, 212, 218, 246, with Mercedes key programmer- vvdi mb bga tool 2.0.4. Here is the instruction for you.
Tool used:
laptop
Successfully added BGA key includes:
Mercedes Benz W166, 197, 212, 218, 246
Step-by-step procedure to add bga key:
Step 1 Read EIS data
Connect VVDI MB BGA Tool to the laptop.
Go to EIS Tools. And click Read EIS data.
Reading data success.
Step 2 Password Calculation
Go to Password Calculation.
Select the Chassis: W166, 197, 212, 218, 246 and Mode: OBD
And click Data Acquisition.
Do follow the prompt on the screen.
Insert the working key to EIS, and then click OK to go on.
Insert working key to Device IR Reader, and click OK.
Insert the working key to EIS, and then click OK.
Insert working key to Device IR Reader, and click OK.
Processing data acquisition... (5 minute needed)
Insert the working key to EIS, and then click OK.
Insert working key to Device IR Reader, and click OK.
Data reading success.
Save data.
Step 3 Upload data to send acquisition data
Acquisition finished. Click OK.
Upload the saved data with Upload Data for password.
Upload success. Click OK.
Step 4 Queue result to get result
Queue number 1, require 1 minute to finish. Click OK.
Find correct password. Click Copy.
Password was copied to clip board.
Step 5 Paste password and save EIS data
Go to EIS Tools.
Click Read EIS data.
Click Paste to get key password.
Click Save EIS data.
Click OK to save HC05 format file.
Step 6 Prepare key file
Go to Prepare Key File.
Click Load EIS file.
Select the file to load, and click Prepare Key File.
Prepare Key File...
Save key file.
Preparing keys...
All key files
Step 7 Read and Write Key
Go to Read Write Key.
Click Identification key.
Reading data success.
Again, click Identification key.
Reading data success.
Click Load key file to get it. (here: key8_F7CCD165_used_051)
Click Write.
Writing data success.
Click Identification key.
Reading data success.
Add BGA key success.
Other successful case about vvdi mb tool:
Change EIS on W172, 204, 207....OK
Calculate EIS 221 password....OK
All key lost on W172, 204, 207....OK
Read and renew ELV on W204, 207, 212....OK
Renew EIS on W172 204 207....OK