UK SHIP, NO TAX

Showing posts with label Land Rover diagnostic tool. Show all posts
Showing posts with label Land Rover diagnostic tool. Show all posts

Monday, 20 March 2017

JLR SDD experiences: Cabin Fuse Box – Fuse #43

I wanted to share some of my experiences for future forum users encountering issues using JLR SDD. For the last month I have been trying to solve several problems using SDD (Multiple module Red X, DTC’s and when trying to run an SDD program asking to connect a J1962 diagnostic cable)
ModulesJLR-SDD-OK

JLR-SDD-New

A significant observation was the battery symbol, top right corner, has always shown red and this is a known concern. However I have always used a battery maintainer reliably delivering 13.7V and up to 40A capacity so what gives  I finally traced the root cause to a blown Fuse 43 in the cabin fuse box. This fuse protects the circuit that delivers B+ to the DLC (Data Link Connector AKA OBD port). With that corrected I get a reliable SDD Battery indicator of green or yellow
JLR-SDD-old

Also I no longer get an SDD request to connect a J1962 diagnostic cable and ran through a vehicle scan successfully.
Now the next interesting observation was that all those ISO network module issues disappeared
SDD-Key-programming-Lite

So when using SDD always use a battery maintainer or charger to help the battery provide sufficient voltage/current. If you still have issues check passenger fuse 43 if you are having strange SDD behaviors and avoid chasing down false positives and stripping out the driver and passenger footwells and drivers door module like me. Well on the bright side I at least cleaned most connectors with zero residue electrical cleaner
Now I need to find out why service functions no longer provide an option to program keys. Why is this all so difficult – oh I Know it’s a Jaguar. Any advise on how to get the key programming option back?


Problem resolution.. Here you go….

You are going to become the mongoose guru.

I am still trying various versions of SDD to see which one I can to work the best with my setup.

Currently installing V130_V7 because:
V1.25 did not work. After reading my VIN it just said the VIN is not authenticated/recognised and returned to the read Vin page.
V1.42 seemed to work (but I didn’t know what to expect with it, so it maybe working).
V1.39 – have the DVD with main V1.39_vull.exe file but no VDF files or SPA files with it, so useless.

I have even tried installing and running it on an old Sony Viao desktop that I keep in the garage for research and music while working on the cars/bike. SDD does not work on a Desktop for some reason, it only seems to work on laptops?

I have tried using SDD with the ignition on (engine off) and ignition on (engine running) as I don’t have a battery voltage maintainer (other than a small motorbike charger with 9000mah).

This whole thing is a learning process and I don’t even know yet if my mongoose cable is now still working (it flashes green and red when connected) because sometimes it reads the VIN and sometimes it doesn’t!!

It’s a work in progress.
This article support by obd2express.co.uk officail blog:http://blog.obdexpress.co.uk/2017/03/21/jlr-sdd-cabin-fuse-box-fuse-43/



Thursday, 10 December 2015

How to install JLR SDD V143 for VXDIAG VCX NANO

Come to learn how to install VXDIAG VCX NANO for Land Rover and Jaguar SDD V143.
JLR SDD V143 for VXDIAG VCX NANO
Operation system:
Windows XP
JLR SDD installation guide:
Preparation
Part 1 Install SDD
Part 2 Install VDF_JA
Part 3 Install VDF_JV
Part 4 Install Additional Pinpoint Tests
Part 5 Install SDD 143.01.001
Part 6 Install VDF_LA
Part 7 Install VDF_LV
Part 8 Install VX Manager
Part 9 Install software for USB ...
Part 10 Install JLR SDD
Part 11 Run JLR SDD
Part I2 Install Deep Freeze
Preparation
Note: please disconnect the internet connection when installing and using JLR143.
Click the laptop icon on the Desktop menu bar to open network connection.
Disable all network connection Local Area Connection & Wireless Network Connection &....
Part 1 Install SDD
Open My Computer>>143-1(F:), to copy “Driver” “DF5td” “DFStd_KEY” to Desktop.
Open “SDD143.00_FULL”.
Select setup language to continue.
Click Yes to restart your computer.
Click Next.
Installing...
Click Next for installing SDD.
Select “I accept... agreement” and click Next.
Tick on “I have read and understand...” and click Next.
Destination: click Next.
Languages: click Next.
Click Install to begin installation.
Installing SDD...
Click Next to install M0XA UPort 1110/1130/1150 Windows Driver.
Destination location: click Next.
Start menu folder: click Next.
Click Install to begin installation.
Installing M0XA UPort 1110/1130/1150 Windows Driver.
Click Finish for installation of M0XA UPort 1110/1130/1150 Windows Driver.
Go on installing SDD...
Click Finish when successfully installing SDD and restart your computer.
Part 2 Install VDF_JA
Open My Computer>>143-1(F:)>>VDF_JA_143.
Choose setup language.
Installing...
Click Finish after successfully installing VDF_JA.
Part 3 Install VDF_JV
Close all the interface, and reopen My Computer>>143-2(F:)>>VDF_JV_143.
Choose setup language.
Installing...
Click Finish after successfully installing VDF_JV.
Part 4 Install Additional Pinpoint Tests
Open My Computer>>143-2(F:)>>SPA_143.
Prompt: Additional Pinpoint Tests will be installed as a background task. Click OK.
Installing Additional Pinpoint Tests.... (wait for about 1 hour)
Click Finish after installing Additional Pinpoint Tests.
Part 5 Install SDD 143.01.001
Close all the interface, and reopen My Computer>>143-3(F:)>>SDD 143.01.
Click Yes to restart your computer.
Installing SDD 143.01...
Click Finish after installing SDD 143.01.001, and restart your computer.
Part 6 Install VDF_LA
Close all the interface, and reopen My Computer>>143-3(F:)>>VDF_LA_143.
Choose setup language.
Installing...
Click Finish after installing VDF_LA.
Part 7 Install VDF_LV
Open My Computer>>143-3(F:)>>VDF_LV_143.
Choose setup language.
Installing...
Click Finish after installing VDF_LV.
Part 8 Install VX Manager
Open Driver on Desktop, then to open VX Manager1.0.5.0612.
Click Next to install VX Manager1.0.5.0612.
Click “I accept the agreement” and Next.
Click Next.
Installing VX Manager...
Installing VCX SDK Driver...
Click Close when installation complete.
Click Finish when VX Manager is installed successfully.
Restart your computer.
Part 9 Install software for USB ...
Found New Hardware Wizard: click Next, with selection of “Install...(Recommend)”.
Installing...
Click Finish for installing software for USB Serial Converter.
Found New Hardware Wizard: click Next, with selection of “Install...(Recommend)”.
Installing...
Click Finish for installing software for USB Serial Port.
Right click My Computer for Manage.
Select Device Manager>>Ports (COM&LPT)>>USB Serial Port (COM4).
Then close computer management.
Part 10 Install JLR SDD
Open VX Manager on Desktop.
JLR SDD V143 for VXDIAG VCX NANO-1
Click License to read and then back to Information.
JLR SDD V143 for VXDIAG VCX NANO-2
Select Diagnostic Apps>>My Apps>>JLR SDD.
JLR SDD V143 for VXDIAG VCX NANO-3
Click Install.
Click Close when installation complete.
Close all the interfaces.
Part 11 Run JLR SDD
Open JLR SDD on Desktop.
Close Setup Windows Internet Explorer 8 interface.
Internet Explorer - Search Provider Default: click OK.
Manage Add-ons: click Close.
Loading...
JLR SDD V143 for VXDIAG VCX NANO-4
Click Continue.
JLR SDD V143 for VXDIAG VCX NANO-5
Click Continue.
Enter dealer information and click Continue.
JLR SDD V143 for VXDIAG VCX NANO-6
SDD warning: click Continue.
Click Proceed with SDD.
JLR SDD V143 for VXDIAG VCX NANO-7
Enter VIN, and click Identify Vehicle.
JLR SDD V143 for VXDIAG VCX NANO-8
Click Proceed with SDD.
Select Low line instrument cluster, and save data.
Click Diagnosis.
JLR SDD V143 for VXDIAG VCX NANO-9
Select Powertrain>>Engine system>>Engine cooling, and click Continue.
JLR SDD V143 for VXDIAG VCX NANO-10
Select CAN_HS>>PCI>>Rerun data collect for this module.
JLR SDD V143 for VXDIAG VCX NANO-11
Click Diagnosis at the bottom.
Click Continue.
Loading recommended candidates...
Close the interface .
JLR Application Launcher: select Stop Application.
Part I2 Install Deep Freeze
Open “DFStd” on Desktop.
Click Next.
Click “I accept...agreement” to go on.
Open “DFStd_KEY” on Desktop, to copy the license key for entering. Click Next.
Click Next, with the only selection of C: (cancel ticks on D: & E:)
Click Install.
Then restart your computer after installation Deep Freeze.
Done!
Top 5 Reasons to get VXDIAG VCX NANO:
1. Replacement of OEM tool of SPX VCM and i-VIEW
2. Support all protocols of Land rover and Jaguar
3.Multi-languages:English/Japanese/Portuguese/Romanian/Korean/Dutch/Polish/Turkish/Spanish/French/Italian/Croatian/Danish/German/Swedish/Finnish/Slovenian/Czech/Russian/Greek/Chinese
4. Supported Car Models: Diesel and gasoline cars
5. Update by CD, without firmware locked