With the auto code reader use of time, the high-temperature heat in the engine work and normal maintenance norms fold, pulling, bending and other brutal demolition methods may lead to the spark plug internal core wire is removed off itself resistance is greatly increased, so that the high-voltage can not be completely adequate transport the spark plug leaving the spark plug off the fire "or" flash over energy is not enough, can not ignite the combustible mixture, the corresponding cylinder can not do work or does not work properly, serious impact on the output of the engine power.
Defective ignition system is caused by unstable idle, unhappy refueling failure phenomenon, and the culprit is damage to the spark plug, and high-voltage lines. Ordinary spark plugs need to be replaced once every 40000km, the expensive platinum compared to the fire mouth 100000km replacement. When using a deadline auto diagnostic tool to mercilessly must be replaced.
The Accord sedan generator indicator light
A 96 models auto scanner of the Honda Accord sedan, the generator charging indicator light is on the dashboard.
Check analysis, because the car uses eight AC generator, electronic tuning regulator is within. Therefore, first check the fuse generator, intact. Measuring the generator 4 terminal connector on the black / yellow wire voltage is 12V normal charge generator on the white / blue wire grounding, dashboard indicator lights, disconnect the grounding, the direction extinguished.
Thus concluded the normal generator outside line fault location on the built-in generator regulator.
Replace the regulator, Launch X431 and troubleshooting.